Delta-Therm IN120-5-CBT Industrial Series Heat Trace Cable, 5 Watts / Ft, 120V, 75 Ft Coil

(No reviews yet) Write a Review
$609.38

Usually Ships In 2 Business Days

Free ground shipping to the lower 48 states

Product ID:
Delta-Therm-IN120-5-CBT-75FT
Weight:
6.00 (Lbs.)
Ships By:
Free Ground
Ships From:
Massachusetts - Vendor Direct

choose options:

Frequently Bought Together

Please choose options for all selected products

Description:

Delta-Therm IN120-5-CBT Industrial Series Heat Trace Cable:
- 75 Ft. coil.
- 5 Watts / Ft.
- 120V.
- Self-Regulating Cable.
- Increases heat output as temperature decreases, and conversely, decreases heat output as temperature increases.
- This cable is intended for use on metal and plastic pipes.
- Industrial Series cables contain two parallel bus wires electrically connected by a web of PTC (positive temperature
coefficient) conductive polymer.
- A thermoplastic elastomer jacket surrounds the cable to provide mechanical protection and electrical isolation.
- A tinned copper metal braid provides additional mechanical protection as well as a ground path for fault currents.

APPLICATIONS
- External Pipe Tracing.

APPROVALS
Ordinary: IN Series cables are FM approved and CSA certified for pipe tracing when used with a PCK-IN connection kit (FM) or PCK-HLC (CSA).
 
Hazardous: IN Series CB are FM approved and CSA certified for pipe tracing in the following categories:
CSA
Class I, Div. 1 And 2, Grps. A, B, C And D.
Class ll, Div. 1 And 2, Grps. E, F, And G.
Class lll, Div. 1 And 2.
For CSA Certification, Use PCK-HLC.
FM
Class I, Div. 2, Grps B, C, And D.
Class ll, Div. 2, Grps F And G.
Class lll, Div. 2.
For FM Approval, Use PCK-IN.
 