![Markel PHLA20-480360-25.0-24-TDP Electric Hazardous Location Heater, 25 KW, 480V/3Ph Markel PHLA20-480360-25.0-24-TDP Electric Hazardous Location Heater, 25 KW, 480V/3Ph](https://cdn11.bigcommerce.com/s-kf91vy1qfw/images/stencil/500x659/products/74943/433009/markel-phla20-480360-25.0-24-tdp-electric-hazardous-location-heater-25-kw-480v3ph__96086.1682087723.jpg?c=1)
Markel PHLA20-480360-20.0-24-TDP Electric Hazardous Location Heater, 20 KW, 480V/3Ph
Markel
$24,997.12
Usually Ships In 3-4 Weeks
Free ground shipping to the lower 48 states
- Product ID:
- Markel-PHLA20-480360-20-0-24-TDP
- UPC:
- 686334739122
- Weight:
- 350.00 (Lbs.)
- Ships By:
- Truck, Curbside, Back Of Truck
- Ships From:
- Tennessee - Factory Direct
Description:
Markel PHLA20-480360-20.0-24-TDP Electric Hazardous Location Heater Features:
- Not cancelable, not returnable. Before purchasing please double check to confirm this item is correct for your application.
- Not cancelable, not returnable. Before purchasing please double check to confirm this item is correct for your application.
- Cart has anti-static wheels to reduce the risk of static discharge.
- Wheeled cart allows for easy maneuverability.
- Cart has integrated fork-lift channels to provide ease of lifting on to ramps or trucks.
- Excellent for providing seasonal heating in hazardous environments.
- All units have disconnect switch, pilot light, and thermostat - standard.
- 24 Volt control, transformer, and contactor in NEMA 7 enclosure.
- Durable epoxy coating on heater housing.
- Hazardous location unit mounted male / female plug.
- Adjustable louvers; manual reset.
- Made in U.S.A.
- California residents see Prop 65 Warnings.
RATINGS
Catalog Number: 07391202
Model Number: PHLA20-480360-20.0-24-TDP
Agency Rating: ETL-CUS
Air Throw: 43
Amp: 25.1
BTU: 68300
CFM: 2450
KW: 20
Phase: 3
Model Number: PHLA20-480360-20.0-24-TDP
Agency Rating: ETL-CUS
Air Throw: 43
Amp: 25.1
BTU: 68300
CFM: 2450
KW: 20
Phase: 3
Temperature Rise: 26.2
Voltage: 480
Weight (Lbs): 350
Color: Gray Housing/Yellow Cart
Voltage: 480
Weight (Lbs): 350
Color: Gray Housing/Yellow Cart
HAZARDOUS LOCATION RATINGS DEFINITIONS
CLASS I:
Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor.
Equipment does not have surface operating temperature in excess of the ignition temperature of the specific gas or vapor.
Examples Include:
- Offshore and land based drilling rigs, petroleum exploration and testing facilities.
- Petroleum refineries, gasoline storage and dispensing areas.
- Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations.
- Petrochemical companies that manufacture chemicals from gas or oil.
- Dry cleaning facilities where vapors from cleaning fluids may be present.
- Aircraft hangers and fuel servicing areas.
- Utility gas plants and operations involving storage and handling of liquefied petroleum or natural gas.
- Petroleum refineries, gasoline storage and dispensing areas.
- Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations.
- Petrochemical companies that manufacture chemicals from gas or oil.
- Dry cleaning facilities where vapors from cleaning fluids may be present.
- Aircraft hangers and fuel servicing areas.
- Utility gas plants and operations involving storage and handling of liquefied petroleum or natural gas.
GROUP C:
Atmospheres such as but not limited to acetaldehyde, allyl alcohol, hydrogen sulfide, ethylene, carbon monoxide, or other gases or vapors of equivalent hazard.
Atmospheres such as but not limited to acetaldehyde, allyl alcohol, hydrogen sulfide, ethylene, carbon monoxide, or other gases or vapors of equivalent hazard.
GROUP D:
Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard.
Atmospheres such as but not limited to acetone, alcohol, gasoline, lacquer solvent vapors, natural gas, propane or other gases or vapors of equivalent hazard.
CLASS II:
Equipment does not have surface temperature greater than the ignition temperature of the specified dust.
Equipment does not have surface temperature greater than the ignition temperature of the specified dust.
Examples Include:
- Coal preparation plants and other carbon handling or processing areas.
- Grain elevators, flour and feed mills.
- Plants which manufacture, use or store Magnesium or Aluminum powders.
- Plants that have chemical or metallurgical processes.
- Producers of starch products or candy.
- Spice grinding plants, sugar plants and cocoa plants.
- Coal preparation plants and other carbon handling or processing areas.
- Grain elevators, flour and feed mills.
- Plants which manufacture, use or store Magnesium or Aluminum powders.
- Plants that have chemical or metallurgical processes.
- Producers of starch products or candy.
- Spice grinding plants, sugar plants and cocoa plants.
GROUP E:
Atmosphere containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 10^5 OHM - Centimeter.
Atmosphere containing combustible metal dust regardless of resistivity, or other combustible dust of similar hazard characteristics having resistivity of less than 10^5 OHM - Centimeter.
GROUP F:
Atmosphere containing carbon black, charcoal, coal or coke dust.
Atmosphere containing carbon black, charcoal, coal or coke dust.
GROUP G:
Atmospheres containing combustible dust having resistivity of 10^5 OHM-Centimeter or greater.
Atmospheres containing combustible dust having resistivity of 10^5 OHM-Centimeter or greater.
DIVISION I:
A location in which ignitable concentrations of flammable material exist under normal operating conditions.
A location in which ignitable concentrations of flammable material exist under normal operating conditions.
DIVISION II:
Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II.
Locations in which flammable materials will normally be confined within closed containers and escape only in the case of accidental rupture, breakdown or during maintenance operations. Any equipment approved for Division I is automatically also approved for Division II.
SPECIFICATIONS
Heat Exchanger and Elements:
Heavy walled, painted carbon steel with aluminum fins liquid heat exchanger, liquid filled with three-immersion type copper sheathed elements. The elements shall have the highest quality nickel-chromium resistance wire encased in a magnesium oxide dielectric and be hermetically sealed into the heat exchanger core. The heat transfer fluid is Ethylene-glycol solution for operation to -49 degrees F (– 45 degrees C). Stainless steel and aluminum pressure relief valve for overpressure.
Thermal Cutout High Limit Protection and Optional Pilot Light:
The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid filled heat exchanger. A pilot light to indicate power on, is located on control enclosure.
The capillary type manual reset thermal cutout shall be rated for 6000 cycles of service and mounted in the liquid filled heat exchanger. A pilot light to indicate power on, is located on control enclosure.
Motor:
The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for hazardous location and operate at rated voltage of heater, 60 Hz, 1725 RPM.
The motor shall be a permanent split capacitor type, permanently lubricated, ball bearing type. The motor shall be rated for hazardous location and operate at rated voltage of heater, 60 Hz, 1725 RPM.
Control Enclosure:
All controls shall be factory installed and wired in a hazardous location enclosure. Contactors and back-up contactors are heavy duty type and break all ungrounded conductors and be rated for 100,000 cycles at full load. Standard 24-Volt control circuit shall be supplied by internal class II transformer. A factory wired integral thermostat. No fan delay relay.
All controls shall be factory installed and wired in a hazardous location enclosure. Contactors and back-up contactors are heavy duty type and break all ungrounded conductors and be rated for 100,000 cycles at full load. Standard 24-Volt control circuit shall be supplied by internal class II transformer. A factory wired integral thermostat. No fan delay relay.
Disconnect Switch:
Factory mounted and wired hazardous location disconnect switch.
Factory mounted and wired hazardous location disconnect switch.
Cabinet With Adjustable Louvers:
The Cabinet shall be .125 inch Aluminum with powder coated epoxy finish. Bronze fan guards with less than 1/4 inch spacing to cover motor and fan shall conform to OSHA Requirements.
The Cabinet shall be .125 inch Aluminum with powder coated epoxy finish. Bronze fan guards with less than 1/4 inch spacing to cover motor and fan shall conform to OSHA Requirements.
Note:
Before selecting a hazardous location electric heater refer to Article 500 or other applicable standard referenced in the National Electric Code
Before selecting a hazardous location electric heater refer to Article 500 or other applicable standard referenced in the National Electric Code
Videos Hide Videos Show Videos
from our fans
"We have been ordering parts from NorthStock and have been very pleased with the service. The availability shown on the website has always been actual in-stock items, product has always shipped as promised. Knowing you have a vendor you can depend on is key, NorthStock is our first point of contact. Customer service on a level that you do not see very often this day and age. Thanks NorthStock!"
CHRYSTAL FROM FLORIDA