Crandall Stats & Sensors
Crandall Stats & Sensors TC-2931-CS&S Thermostat
Crandall Stats & Sensors
$71.37
Usually Ships In 5-7 Business Days
Free ground shipping to the lower 48 states
- Product ID:
- crandall-stats-sensors-tc-2931-cs&s
- Weight:
- 1.00 (Lbs.)
- Ships By:
- Free Ground
- Ships From:
- Crandall Stats & Sensors In IL
Description:
Crandall Stats & Sensors TC-2931-CS&S Thermostat Features:
- The TC-2931-CS&S Strap-On Type Changeover Thermostats are designed for sensing temperature of fluids in pipes.
- The heating and cooling systems and reversing the control action of the room temperature sensing control.
- These Thermostats contain a bimetal that makes or breaks a SPDT switch.
- The switch is rated for 5.8 FLA, 34.8 LRA, or 125 VA ant 120 VAC. At 240 VAC, the switch is rated at 2.9 FLA, 17.4 LRA or 125 VA.
- The units are mounted directly to a pipe with one or two springs.
- At higher temperatures, the Thermostat’s Blue lead is connected to the Yellow (or Common) lead.
- At lower temperatures, the Red lead connects to the Yellow lead.
- The setpoint for these units is fixed at approximately 75 °F and they have an approximate 15 °F fixed differential.
- The minimum hot water temperature to be sensed is 90 °F and the maximum cold water is 60 °F.
- Springs included for mounting on a Pipe 1 1/2 inch max.
- Weights and Dimensions: Unit – 1 Inch H x 2-1/8 inch W x 3/4 inch D (plus wires)
- Crandall Stats and Sensors is the OEM manufacturer of the TC-2931.
- The TC-2931-CS&S Strap-On Type Changeover Thermostats are designed for sensing temperature of fluids in pipes.
- The heating and cooling systems and reversing the control action of the room temperature sensing control.
- These Thermostats contain a bimetal that makes or breaks a SPDT switch.
- The switch is rated for 5.8 FLA, 34.8 LRA, or 125 VA ant 120 VAC. At 240 VAC, the switch is rated at 2.9 FLA, 17.4 LRA or 125 VA.
- The units are mounted directly to a pipe with one or two springs.
- At higher temperatures, the Thermostat’s Blue lead is connected to the Yellow (or Common) lead.
- At lower temperatures, the Red lead connects to the Yellow lead.
- The setpoint for these units is fixed at approximately 75 °F and they have an approximate 15 °F fixed differential.
- The minimum hot water temperature to be sensed is 90 °F and the maximum cold water is 60 °F.
- Springs included for mounting on a Pipe 1 1/2 inch max.
- Weights and Dimensions: Unit – 1 Inch H x 2-1/8 inch W x 3/4 inch D (plus wires)
- Crandall Stats and Sensors is the OEM manufacturer of the TC-2931.
Videos Hide Videos Show Videos
from our fans
"We have been ordering parts from NorthStock and have been very pleased with the service. The availability shown on the website has always been actual in-stock items, product has always shipped as promised. Knowing you have a vendor you can depend on is key, NorthStock is our first point of contact. Customer service on a level that you do not see very often this day and age. Thanks NorthStock!"