Re-Verber-Ray HL3-30-100P Infrared Tube Heater, Propane, 2 Stage, 115V Power - 24V Control, 100000 BTU, 30 Ft Straight Tube

(No reviews yet) Write a Review
$1,587.60

Usually Ships In 3-4 Weeks

Free ground shipping to the lower 48 states

Product ID:
Re-Verber-Ray-HL3-30-100P
Weight:
160.00 (Lbs.)
Ships By:
Truck, Curbside, Back Of Truck
Ships From:
Michigan - Direct From Manufacturer

Frequently Bought Together

Please choose options for all selected products

Description:

Re-Verber-Ray HL3-30-100P Infrared Tube Heater, Propane, 2 Stage, 115V Power - 24V Control, 100000 BTU, 30 Ft Straight Tube

HL3 Series

PREMIER, TWO STAGE, LOW INTENSITY INFRARED HEATER

The HL3 series, packed with quality features, represents today’s most energy efficient line of infrared tube heaters. Our patented two stage technology, incorporated into the HL3 series, provides more comfort while saving valuable energy dollars. In addition, the highest quality materials and construction features ensure years of reliable and efficient operation. No other infrared heater can match the performance and quality of the HL3 series.

Re-Verber-Ray HL3-30-100P Infrared Tube Heater Features:
- Propane.
- 2 Stage gas control.
- 30 Ft. straight tube and reflector system.
- 120 Volt main power / 24 Volt control power.
- 100 percent aluminized steel tubes with .95 emissive coating.
- Pre- and post-purge controls.
- Self-diagnostic LED, microprocessor based circuitry.
- Independent control-air-gas compartments with tool-free access.
- Fitted ABS plastic air intake collar.
- Reliable hot surface ignition.
- 24 volt controls and power cord standard.
 
APPROVALS
- CSA Design Certified.
- Commercial/Industrial Approval.
- Indoor approval.
- Outdoor approval with accessory OD-Kit.
 
BURNER CONTROL BOX
- Sight glass for burner inspection.
- Totally enclosed components.
- Serviceable while in operation.
- Coated enameled steel.
- Operational indicator lights.
 
GAS CONNECTION
- 7/8 in. flare-M FPT connection to 1/2 in. x 24 in.
- Stainless steel flex connector provided.
 
GAS SUPPLY (Inches W.C.)
- Manifold pressure: Natural Gas Units 3.5; Propane Units 10.0
- Min. inlet pressure: Natural Gas Units 5.0; Propane Units 11.0
- Max. inlet pressure: Natural Gas Units 14.0; Propane Units 14.0
 
POWER SUPPLY
- 120 VAC, 60 Hz GRD, 1 Ph., 3-wire.
- 60 in. grounded power cord.
- Ignition current - 4.8 amps.
- Running current - 1.1 amps.
 
CONTROLS
- Two-stage gas valve (at 100 percent and 65 percent)
- Air proving safety switch.
- Silicon carbide hot surface ignition.
- Pre and post purge controls.
- Flame rod sensing.
- 24V thermostatic control voltage.
- Self-diagnostic LED.
 
REFLECTOR
- Highly polished aluminum.
- Two end caps included.
- Reflector tension springs.
- Continuous overlap design.
- One reflector center support per reflector.
 
COMBUSTION AND RADIANT TUBES
- 16ga. 4 inch O.D. aluminized coated steel radiant emitter tubes.
- Titanium coated combustion chamber (150-200 MBH models only).
- All tubes coated with high temperature, corrosion resistant black coating, .95 emissivity.
- Slip-fit swaged tube connection.
- Turbulator baffle.
 
COMBUSTION AIR INLET AND VENTING
- Preset 4 in. combustion air inlet collar.
- Sidewall or roof venting.
 
LIMITED WARRANTY
- 3 year - Burner box components.
- 5 years - Combustion and radiant tubes.
- 10 years - Burner.
Top